Specifications
Measures % Methane (CH4), Carbon Dioxide (CO2), and Oxygen (O2) by Volume, Static Pressure & Differential Pressure
Range: 0 to 100% (CH4), 0 to 60% (CO2), 0 to 25% (O2), 0 to 10" WC (Differential), 0 to 100" WC (Static)
Accuracy: +/-0.3% (CH4 & CO2), +/-1.0% (O2)
Sensors: Infrared (CH4 & CO2) and Galvanic (O2)
Flow Rate: 500 cc/min, Accuracy: +/-3% 5-150 SCFM
Calculates Balance Gas, Flow Rates (SCFM) & Calorific Value (KW or BTU)
Displays % LEL of CH4, Peak CH4, & User-Defined Comments
Records Site & Well Conditions
Extended Operation (10 to 14 Hours Use from One Charge)
Accepts Protocols
Two Instruments in One (GA & GEM Mode)
Certified Intrinsically Safe for Landfill Use